NFPA (Fire) 87 PDF

NFPA (Fire) 87 PDF

Name:
NFPA (Fire) 87 PDF

Published Date:
04/29/2014

Status:
Active

Description:

Recommended Practice for Fluid Heaters, 2015 Edition

Publisher:
National Fire Protection Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
Codes and standards published by NFPA are displayed as read-only under license from NFPA solely for use within this system. NFPA material may not be downloaded, printed, reproduced, or transferred.

Control dangers and ensure safe operation of equipment with updated NFPA 87: Recommended Practice for Fluid Heaters.

NFPA 87: Recommended Practice for Fluid Heaters was created in response to requests from manufacturers, insurance companies, trade associations, and users for safety guidance for fuel-fired and electric fluid heaters. It provides guidance for fluid heaters to minimize the fire and explosion hazards that can endanger the fluid heater, the building, or personnel.

Fluid heaters are used in industrial environments to heat thermal and process fluids of all types; and the heated fluids are used in processes such as textile drying, pressboard manufacturing, gas sweetening, chemical synthesis, plastic molding, hot galvanizing, laminating, dry cleaning, and food processing.

Comprehensive coverage provides the current best practices for:
  • Location and construction
  • Heating systems
  • Commissioning and operations
  • Maintenance, inspection, and testing
  • Heating system safety equipment and application
Updates make NFPA 87 consistent with other NFPA® codes and standards.
  • Added definitions for Burner Management System (BMS), Emergency Shutoff Valve (ESOV), and other revisions correlate with the 2015 NFPA 86: Standard for Ovens and Furnaces.
  • Modified Chapter 6 aligns with NFPA 86 by revising requirements for ESOV, emergency isolation valves, and overpressure protection.
  • Added procedures for placing equipment into service are based on purging practices in the 2015 NFPA 54: National Fuel Gas Code and the 2014 NFPA 56
  • Added requirement prohibiting manifolding vent lines from different pressure levels is based on NFPA 85.
  • Modified requirements for logic systems for both Burner Management System (BMS) logic and PLC systems
  • Revised requirements for Class F heaters in Chapter 9
  • New content for Class G and H heaters in Chapters 10 and 11
Order today to prevent loss of life, property, and production due to fluid heater fires and explosions.
ANSI : ANSI Approved
ISBN(s) : 9781455908967
Number of Pages : 54
Published : 04/29/2014

History

NFPA (Fire) 87
Published Date: 12/01/2023
Standard for Fluid Heaters, 2024 Edition
$44.7
NFPA (Fire) 87
Published Date: 10/05/2020
Standard for Fluid Heaters, 2021 Edition
NFPA (Fire) 87
Published Date: 08/01/2017
Standard for Fluid Heaters, 2018 Edition
NFPA (Fire) 87
Published Date: 04/29/2014
Recommended Practice for Fluid Heaters, 2015 Edition
NFPA (Fire) 87
Published Date: 06/01/2010
Recommended Practice for Fluid Heaters, 2011 Edition

Related products

NFPA (Fire) 72
Published Date: 09/15/2021
National Fire Alarm and Signaling Code, 2022 Edition
$46.5

Best-Selling Products

AS/NZS 10002:2014
Published Date: 10/29/2014
Guidelines for complaint management in organizations
$31.68
AS/NZS 1015:2011
Published Date: 10/07/2011
Records management - Physical storage
$21.582
AS/NZS 1020:1995
Published Date: 03/05/1995
The control of undesirable static electricity
$36.63
AS/NZS 1020:2023
Published Date: 06/02/2023
The control of static electricity in non-hazardous areas
$23.166
AS/NZS 1026:2004
Published Date: 04/29/2004
Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kV
$30.492
AS/NZS 1044:1992
Published Date: 08/17/1992
Limits and methods of measurement of radio interference characteristics of household electrical appliances, portable tools and similar electrical apparatus
$33.264